1
2.5-inch hard disk drive cage
2
2.5-inch hot-swap drive
To install a 2.5-inch hard disk drive cage, complete the following steps:
1. Touch the static-protective package that contains the 2.5-inch disk drive cage to any unpainted metal
surface on the server; then, remove the drive cage from the package.
2. Install both 2.5-inch disk drive backplanes in the back of the drive cage (see Installing a 2.5-inch disk
drive backplane).
3. Slide the 2.5-inch disk drive cage into the opening in the front of the server; then, press drive cage in
until the release latches click into place.
4. Install any hot-swap hard disk drives that were removed from the drive cage (see Installing a 2.5-inch
hot-swap hard disk drive).
5. Close the bezel (see Closing the bezel).
6. Carefully turn the server on its side so that it is lying flat, with the cover facing up.
Attention: Do not allow the server to fall over.
7. Connect the cables to the 2.5-inch disk drive backplane (see "SAS backplane connectors" on page
141 and Internal cable routing and connectors).
8. Install the fan-cage assembly (see Installing the fan-cage assembly).
9. Install the air baffle (see Installing the air baffle).
10. Return the power-supply cage to its closed position (see Closing the power-supply cage).
11. Install the power supplies (see Installing a hot-swap power supply).
12. Install and lock the left-side cover (see Installing the left-side cover).
13. Reconnect the external cables and power cords; then, turn on the attached devices and turn on the
server.

Removing the operator information panel assembly