• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a trained service technician.
The Processor CPU nStatus has
Failed with IERR.(n = microprocessor
number)
An Over-Temperature Condition has
been detected on the Processor CPU
nStatus.(n = microprocessor number)
Error
A processor failed - IERR
condition has occurred.
Error
An overtemperature
condition has occurred
for microprocessor n.(n =
microprocessor number)
1. Make sure that the latest
levels of firmware and device
drivers are installed for
all adapters and standard
devices, such as Ethernet,
SCSI, and SAS.
Important: Some cluster
solutions require specific
code levels or coordinated
code updates. If the device
is part of a cluster solution,
verify that the latest level of
code is supported for the
cluster solution before you
update the code.
2. Run the DSA program for the
hard disk drives and other
I/O devices.
3. (Trained service
technician only) Replace
microprocessor n.
(n = microprocessor number)
1. Make sure that the fans
are operating, that there
are no obstructions to the
airflow, that the air baffle is in
place and correctly installed,
and that the server cover
is installed and completely
closed.
2. Make sure that the heat
sink for microprocessor nis
installed correctly.
3. (Trained service
technician only) Replace
microprocessor n.
(n = microprocessor number)
.
Chapter 5
Diagnostics
33