Table 4. DSA messages (continued)
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 8 "Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823" on page 221 to determine
which components are customer replaceable units (CRU) and which components are field replaceable
units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a Trained service technician.
Message
number
Component Test
201-802-xxx
Memory
201-803-xxx
Memory
201-804-xxx
Memory
104
ThinkServer TD200x Hardware Maintenance Manual
State
Description
Memory
Aborted Test
Test
aborted: the
end address
in the E820
function is
less than 16
MB.
Memory
Aborted Test
Test
aborted:
could not
enable the
processor
cache.
Memory
Aborted Test
Test
aborted:
the memory
controller
buffer
request
failed.
Action
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that all DIMMs are enabled in the
Setup utility.
4. Make sure that the server firmware is at the
latest level. The installed firmware level is
shown in the DSA log in the Firmware/VPD
section for this component. For more
information, see Updating the firmware.
5. Run the test again.
6. If the failure remains, go to the Lenovo Web
site for more troubleshooting information at
http://www.lenovo.com/support.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the server firmware is at the
latest level. The installed firmware level is
shown in the DSA log in the Firmware/VPD
section for this component. For more
information, see Updating the firmware.
4. Run the test again.
5. If the failure remains, go to the Lenovo Web
site for more troubleshooting information at
http://www.lenovo.com/support.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the server firmware is at the
latest level. The installed firmware level is
shown in the DSA log in the Firmware/VPD
section for this component. For more
information, see Updating the firmware.
4. Run the test again.
5. If the failure remains, go to the Lenovo Web
site for more troubleshooting information at
http://www.lenovo.com/support.