Lenovo ThinkServer TD200x Hardware Maintenance Manual page 88

Hardware maintenance manual for td200x
Hide thumbs Also See for ThinkServer TD200x:
Table of Contents

Advertisement

1
ac power LED
2
dc power LED
3
Power error LED
The following table describes the problems that are indicated by various combinations of the power-supply
LEDs and the system power LED on the operator information panel and suggested actions to correct
the detected problems.
Table 3. Power-supply LEDs
Power-supply LEDs
AC
DC
Error
Off
Off
Off
Off
Off
On
Off
On
Off
Off
On
On
80
ThinkServer TD200x Hardware Maintenance Manual
Description
Action
No ac power to
1. Check the ac power to the server.
the server or a
2. Make sure that the power cord is
problem with the
connected to a functioning power
ac power source
source.
3. Turn the server off and then turn the
server back on.
4. If the problem remains, replace the
power supply.
No ac power
1. Replace the power supply.
to the server or
2. Make sure that the power cord is
a problem with
connected to a functioning power
the ac power
source.
source and the
power supply
had detected an
internal problem
Faulty power
Replace the power supply.
supply
Faulty power
Replace the power supply.
supply
Notes
This is a normal
condition when no
ac power is present.
This happens only
when a second
power supply is
providing power to
the server.