Removing the fan cage assembly

To remove the air baffle, do the following:
1. Read the safety information (see Safety information).
2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables.
3. Turn the server on its side so that it is lying flat, with the side cover facing up.
4. Unlock and remove the left-side cover (see Removing the left-side cover).
5. Remove the hot-swap power supply or power supplies from the power-supply cage (see Removing
a hot-swap power supply).
6. Rotate the power-supply cage to its open position (see Opening the power-supply cage).
7. If any full-length PCI adapters are installed, remove them (see Removing an adapter).
8. Remove the air baffle (see Removing the air baffle).
9. Press the fan cage release latches on each side of the fan cage toward the sides of the server. The
fan cage will lift up slightly when the release latches are fully open.
10. Grasp the fan-cage assembly and lift it out of the server.
11. If you are instructed to return the fan-cage assembly, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.