Lenovo ThinkServer TD200x Hardware Maintenance Manual page 180

Hardware maintenance manual for td200x
Hide thumbs Also See for ThinkServer TD200x:
Table of Contents

Advertisement

3. Remove the three fan air baffles
4. Install the three hot-swap fans
1
Release latch
2
Hot-swap power supply
5. Remove the power supply filler from the second power supply bay.
6. Slide the new power supply partially into the empty power supply bay. Pinch the orange release latch
and push the power supply the rest of the way into the bay until it is seated.
7. Install the left-side cover.
8. Connect one end of the new power cord into the connector on the back of power supply, and connect
the other end of the power cord to a properly grounded electrical outlet.
9. Make sure that the ac power LED on the top of each power supply is lit, indicating that the power
supply is operating correctly. If the server is turned on, make sure that the dc power LED on the top of
the power supply is lit also.
If you have other optional devices to install or remove, do so now. Otherwise, go to Completing the
installation.
172
ThinkServer TD200x Hardware Maintenance Manual
1
from the fan bays of the fan cage assembly.
2
in the empty bays of the fan cage assembly.

Advertisement

Table of Contents
loading

Table of Contents