Lenovo ThinkServer TD200x Hardware Maintenance Manual page 82

Hardware maintenance manual for td200x
Hide thumbs Also See for ThinkServer TD200x:
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
• See the Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a trained service technician.
Lit EasyLED
diagnostics
LED with the
system-error or
information LED
also lit
VRM
74
ThinkServer TD200x Hardware Maintenance Manual
Description
A VRM has failed.
Action
a. Check the system-event log to determine the
reason for the lit LED (for a VRM).
b. Determine whether the CNFG LED is also lit. If
the CNFG LED is lit, the memory configuration is
invalid. Reseat the VRM.
c. If the CNFG LED is not lit, reseat the following
components:
1) Failing VRM
2) (Trained service technician only)
Microprocessor associated with the
VRM
d. Replace the following components one at a time,
in the order shown, restarting the server each
time:
1) Failing VRM
2) (Trained service technician only)
Microprocessor associated with the
VRM
3) (Trained service technician only) System
board