Lenovo ThinkServer TD200x Hardware Maintenance Manual page 58

Hardware maintenance manual for td200x
Hide thumbs Also See for ThinkServer TD200x:
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a trained service technician.
A PCI SERR has occurred
on system %1.(%1 =
CIM_ComputerSystem.ElementName)
Fault in slot System board
on system %1.(%1 =
CIM_ComputerSystem.ElementName)
50
ThinkServer TD200x Hardware Maintenance Manual
Error
A PCI SERR has
occurred.(Sensor = One
of PCI Err)
Error
1. Check the extender-card
LEDs.
2. Reseat the affected adapters
and extender card.
3. Update the server and
adapter firmware (UEFI and
IMM).
Important: Some cluster
solutions require specific
code levels or coordinated
code updates. If the device
is part of a cluster solution,
verify that the latest level of
code is supported for the
cluster solution before you
update the code.
4. Remove both adapters.
5. Replace the PCIe adapter.
6. Replace the extender card.
7. (Trained service technician
only) Replace the system
board.
1. Check the extender-card
LEDs.
2. Reseat the affected adapters
and extender card.
3. Update the server and
adapter firmware (UEFI and
IMM).
Important: Some cluster
solutions require specific
code levels or coordinated
code updates. If the device
is part of a cluster solution,
verify that the latest level of
code is supported for the
cluster solution before you
update the code.
4. Remove both adapters.
5. Replace the PCIe adapter.
6. Replace the extender card.
7. (Trained service technician
only) Replace the system
board.

Advertisement