1
Release latch
2
Control panel assembly
To remove the operator information panel assembly, complete the following steps:
1. Read the safety information that begins on page Safety information.
2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables.
3. Unlock and remove the left-side cover (see Removing the left-side cover).
4. Open the bezel (see Opening the bezel).
5. Remove the power supply or power supplies from the power-supply cage (see Removing a hot-swap
power supply).
6. Rotate the power-supply cage to its open position (see Opening the power-supply cage).
7. Remove the air baffle (see Removing the air baffle).
8. Remove the fan-cage assembly (see Removing the fan cage assembly).
9. Disconnect the operator information panel assembly cable from the system board (see System-board
internal connectors).
10. Locate the operator information panel assembly release latch just above the DVD drive.
11. Push up on the release latch while you pull the operator information panel assembly toward the rear of
the server; then, angle the back of the assembly toward the system board and remove the assembly
from the server.
12. If you are instructed to return the operator information panel assembly, follow all packaging instructions,
and use any packaging materials for shipping that are supplied to you.

Installing the operator information panel assembly

1
Release latch
2
Control panel assembly
.
Chapter 7
Installing optional devices and replacing customer replaceable units
195