Lenovo ThinkServer TD200x Hardware Maintenance Manual page 204

Hardware maintenance manual for td200x
Hide thumbs Also See for ThinkServer TD200x:
Table of Contents

Advertisement

To install the operator information panel assembly, complete the following steps:
1. Touch the static-protective package that contains the operator information panel assembly to any
unpainted metal surface on the server; then, remove the assembly from the package.
2. Angle the operator information panel assembly so that the edge of the assembly is in the guide slot.
3. Slide the operator information panel assembly forward until the release latch clicks into place.
4. Connect the operator information panel assembly cable to the system board (see System-board internal
connectors and Internal cable routing and connectors).
5. Install the fan-cage assembly (see Installing the fan-cage assembly).
6. Install the air baffle (see Installing the air baffle).
7. Return the power-supply cage to its closed position (see Opening the power-supply cage).
8. Install the hot-swap power supply or power supplies (see Installing a hot-swap power supply).
9. Close the bezel (see Closing the bezel).
10. Install and lock the left-side cover (see Installing the left-side cover).
11. Reconnect the external cables and power cords; then, turn on the attached devices and turn on the
server.