Installing The Fan-Cage Assembly; Removing The Battery - Lenovo ThinkServer TD200x Hardware Maintenance Manual

Hardware maintenance manual for td200x
Hide thumbs Also See for ThinkServer TD200x:
Table of Contents

Advertisement

Installing the fan-cage assembly

1
Fan cage assembly
2
Fan cage assembly release buttons
To install the fan-cage assembly, do the following:
1. Align the guides on the fan cage with release latches on each side.
2. Push the fan-cage assembly into the server until it clicks into place.
3. If you removed any full-length PCI adapters, install them (see Installing an adapter).
4. Install the air baffle (see Installing the air baffle).
5. Return the power-supply cage to its closed position (see Closing the power-supply cage).
6. Install the hot-swap power supply or power supplies (see Installing a hot-swap power supply).
7. Install and lock the left-side cover (see Installing the left-side cover).
8. Reconnect the external cables and power cords; then, turn on the attached devices and turn on the
server.

Removing the battery

To remove the battery, do the following:
1. Read the safety information that begins on page Safety information.
2. Turn off the server and all attached devices.
3. Disconnect all external cables and power cords.
4. Turn the server on its side so that it is lying flat, with the side cover facing up.
5. Unlock and remove the left-side cover (see Removing the left-side cover).
6. Locate the battery on the system board (see System-board internal connectors).
.
Chapter 7
Installing optional devices and replacing customer replaceable units
167

Advertisement

Table of Contents
loading