• Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
• See Chapter 8 "Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823" on page 221 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a trained service technician.
Lit EasyLED
diagnostics
LED with the
system-error or
information LED
also lit
IMM heartbeat LED
PCI slot 1 to PCI slot
8 error LEDs
H8 heartbeat LED

Remind button

You can use the remind button on the EasyLED panel to put the system-error LED on the operator
information panel into Remind mode. When you press the remind button, you acknowledge the error but
indicate that you will not take immediate action. The system-error LED flashes while it is in Remind mode
and stays in Remind mode until one of the following conditions occurs:
• All known errors are corrected.
• The server is restarted.
• A new error occurs, causing the system-error LED to be lit again.

Power-supply LEDs

The following illustration shows the power-supply LEDs on the rear of the server.
Description
Indicates the status of the boot
process of the IMM.
When the server is connected to
power this LED flashes quickly
to indicate that the IMM code
is loading. When the loading is
complete, the LED stops flashing
briefly and then flashes slowly
to indicate that the IMM if fully
operational and you can press the
power-control button to start the
server.
An error has occurred on a PCI
bus or on the system board. An
additional LED is lit next to a failing
PCI slot.
Indicates the status of power-on
and power-off sequencing.
Action
If the LED does not begin flashing within 30 seconds
of when the server is connected to power, complete
the following steps:
a. (Trained service technician only) Use the IMM
recovery switch to recover the firmware (see
"System board switches and jumpers" on page
129).
b. (Trained service technician only) Replace the
system board.
a. Check the system-event log for information about
the error.
b. If you cannot isolate the failing adapter through
the LEDs and the information in the system-event
log, remove one adapter at a time, and restart the
server after each adapter is removed.
c. If the failure remains, go to
http://www.lenovo.com/support for additional
troubleshooting information.
a. If the H8 heartbeat LED is blinking at a 1 Hz rate,
no action is necessary.
b. (Trained service technician only) If the H8
heartbeat LED is not blinking, replace the system
board.
79
.
Chapter 5
Diagnostics