Description - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Extended setpoint channel

2.2 Description

2.2
Description
In the extended setpoint channel, setpoints from the setpoint source are conditioned for
motor control.
The setpoint for motor control can also originate from the technology controller (see
"Technology controller").
Figure 2-1
Properties of the extended setpoint channel
● Main/supplementary setpoint, setpoint scaling
● Direction of rotation limiting and direction of rotation changeover
● Suppression bandwidths and setpoint limitation
● Ramp function generator
Setpoint sources
The closed-loop control setpoint can be interconnected from various sources using BICO
technology (e.g. to p1070 CI: main setpoint (see function diagram 3030)).
There are various options for setpoint input:
● Fixed speed setpoints
● Motorized potentiometer
48
Extended setpoint channel
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
Drive Functions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents