Inputs/Outputs; Overview Of Inputs/Outputs - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Basic information about the drive system

12.5 Inputs/outputs

Changing scaling parameters p2000 to p2007
CAUTION
If a referenced form is selected and the reference parameters (e.g. p2000) are changed
retrospectively, the referenced values of some of the control parameters are also adjusted
to ensure that the control behavior is unaffected.
12.5
Inputs/outputs
12.5.1

Overview of inputs/outputs

The following digital/analog inputs/outputs are available:
Table 12-6
Overview of inputs/outputs
Component
CU310
CU320
TB30
TM15
TM31
Relay outputs: 2
Temperature sensor input: 1
TM41
Incremental encoder emulation: 1 (see also the Function Manual)
1) Variable: floating or non-floating
2) 6 of these are "high-speed inputs"
3) 3 of these are "high-speed inputs"
Note
For detailed information about the hardware properties of I/Os, please refer to:
Reference: /GH1/ SINAMICS S120 Equipment Manual: Control Units
For detailed information about the structural relationships between all I/Os of a component
and their parameters, please refer to the function diagrams in:
Reference: /LH1/ SINAMICS S List Manual
484
Digital
Inputs
Bidirectional
inputs/outputs
4
4
1)
8
8
1)
4
-
24
8
4
Outputs
3)
2)
-
4
-
4
-
4
-
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
Analog
Inputs
Outputs
2
2
-
-
2
2
1
-
Drive Functions