Advertisement

Extended setpoint channel
2.9 Ramp-function generator
Parameterization with STARTER
The "ramp function generator" parameter screen is selected via the following icon in the
toolbar of the STARTER commissioning tool:
Figure 2-12
Overview of key parameters (see SINAMICS S List Manual)
Adjustable parameters
● p1115 Ramp function generator selection
● p1120[DDS] Ramp function generator ramp-up time
● p1121[DDS] Ramp function generator ramp-down time
● p1122[CDS] BI: Bypass ramp function generator
● p1130[DDS] Ramp function generator initial rounding-off time
● p1131[DDS] Ramp function generator final rounding-off time
● p1134[DDS] Ramp function generator rounding-off type
● p1135[DDS] OFF3 ramp-down time
● p1136[DDS] OFF3 initial rounding-off time
● p1137[DDS] OFF3 final rounding-off time
● p1140[CDS] BI: Enable ramp generator
● p1141[CDS] BI: Start ramp function generator
● p1143[CDS] BI: Ramp function generator, accept setting value
● p1144[CDS] CI: Ramp function generator setting value
● p1145[DDS] Ramp function generator tracking
● p1148 [DDS] Ramp function generator tolerance for ramp-up and ramp-down active
● p1151 [DDS] Ramp function generator configuration
Display parameters
● r1119 CO: Ramp function generator setpoint at the input
● p1149 Ramp function generator acceleration
● r1150 CO: Ramp function generator speed setpoint at the output
64
STARTER icon for "ramp function generator"
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4