3. Free telegrams (p0922 = 999)
Receive process data
DWORD
connector output
WORD connector
output
Binector output
Free binector-
connector
converter
Send process data
DWORD
connector input
WORD connector
input
Free connector-
binector converter
Telegram interconnections
When you change p0922 = 999 (factory setting) to p0922 ≠ 999, the telegrams are
interconnected and blocked automatically.
Note
Telegrams 20, 352 are the exceptions. Here, PZD06 in the transmit telegram and PZD03 to
PZD06 in the receive telegram can be interconnected as required.
When you change p0922 ≠ 999 to p0922 = 999, the previous telegram interconnection is
retained and can be changed.
Note
If p0922 = 999, a telegram can be selected in p2079. A telegram interconnection is
automatically made and blocked. The telegram can also be extended.
This is an easy method of creating extended telegram interconnections on the basis of
existing telegrams.
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
The send and receive telegrams can be configured as required by using BICO technology
to interconnect the send and receive process data.
SERVO, TM41
r2060[0 ... 14]
r2050[0 ... 15]
p2080[0 ... 15], p2081[0 ... 15], p2082[0 ... 15], p2083[0 ... 15] / r2089[0 ... 3]
p2061[0 ... 14]
p2051[0 ... 18]
Communication PROFIBUS DP/PROFINET IO
10.1 Communications according to PROFIdrive
VECTOR
r2060[0 ... 30]
r2050[0 ... 31]
r2090.0 ... 15
r2091.0 ... 15
r2092.0 ... 15
r2093.0 ... 15
p2061[0 ... 30]
p2061[0 ... 31]
p2099[0 ... 1] / r2094.0 ... 15, r2095.0 ... 15
CU_S
A_INF, B_INF,
S_INF, TB30,
TM15DI/DO
-
r2050[0 ... 4]
r2090.0 ... 15
r2091.0 ... 15
-
p2051[0 ... 14]
p2051[0 ... 4]
TM31,
349