Siemens SINAMICS S120 Function Manual page 369

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Bit
Meaning
4
DDS eff., bit 4
5, 6
Reserved
7
Parking axis
8
Travel to fixed endstop
9, 10 Reserved
11
Data set changeover
12
Drive unit sign-of-life bit 0
13
Drive unit sign-of-life bit 1
14
Drive unit sign-of-life bit 2
15
Drive unit sign-of-life bit 3
NACT_A (Speed setpoint A (16 bit))
● Actual speed value with 16-bit resolution.
● The speed actual value is normalized in the same way as the setpoint (see NSOLL_A).
NACT_B (Speed setpoint B (32 bit))
● Actual speed value with 32-bit resolution.
● The speed actual value is normalized in the same way as the setpoint (see NSOLL_B).
Gn_ZSW (encoder n status word)
Gn_XIST1 (encoder n position actual value 1)
Gn_XIST2 (encoder n position actual value 2)
This process data belongs to the encoder interface.
ITIST_GLATT
The actual current value smoothed with p0045 is displayed.
MELDW (message word)
See function diagram [2456]
Table 10-14 Description of MELDW (message word)
Bit
Meaning
0
Ramp-up/ramp-down completed /
ramp-function generator active
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
Comments
1
Axis parking active
0
Axis parking not active
1
Travel to fixed endstop
0
No travel to fixed stop
1
Data record changeover active
0
No data set changeover active
User data integrity (4-bit counter)
Comments
1
Ramp-up/ramp-down completed.
The ramp-up procedure is completed once the
speed setpoint has been changed.
Communication PROFIBUS DP/PROFINET IO
10.1 Communications according to PROFIdrive
BICO
BO: r0051.4
BO: r0896.0
BO: r1406.8
BO: r0835.0
Implicitly
interconnected
BICO
BO: r2199.5
369

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents