Simatic Hmi Addressing - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Communication PROFIBUS DP/PROFINET IO
10.2 Communication via PROFIBUS DP
10.2.2.4

SIMATIC HMI addressing

You can use a SIMATIC HMI as a PROFIBUS master (master class 2) to access SINAMICS
directly. With respect to SIMATIC HMI, SINAMICS behaves like a SIMATIC S7. For
accessing drive parameters, the following simple rule applies:
● Parameter number = data block number
● Parameter sub-index = bit 0 - 9 of data block offset
● Drive object number = bit 10 - 15 of data block offset
Pro Tool and WinCC flexible
The SIMATIC HMI can be configured flexibly with "Pro Tool" or "WinCC flexible".
The following specific settings for drives must be observed when configuration is carried out
with Pro Tool or WinCC flexible.
Controllers: Protocol always "SIMATIC S7 – 300/400"
Table 10-29 Other parameters
Network parameter profile
Network parameter baud rate
Communication partner address
Communication partner
slot/subrack
Table 10-30 Tags: "General" tab
Name
Control
Type
Area
DB
(data block number)
DBB, DBW, DBD
(data block offset)
Length
Acquisition cycle
414
Field
Field
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
Value
DP
Any
PROFIBUS address of the drive unit
don't care, 0
Value
Any
Any
Depending on the addressed parameter value,
e.g.:
INT: for integer 16
DINT: for integer 32
WORD: for unsigned 16
REAL: for float
DB
Parameter number
1 ... 65535
Drive object no. and subindex
Bit 15 – 10: Drive object no. 0 ... 63
Bit 9 – 0: Sub-index 0 ... 1023
In other words:
DBW = 1024 * drive object no. + sub-index
Not activated
Any
Drive Functions