Description
The inverter described in this manual is a device for controlling an induction motor or a
synchronous motor. The inverter is designed for installation in electrical installations or
machines.
It has been approved for industrial and commercial use on industrial networks. Additional
measures have to be taken when connected to public grids.
The technical specifications and information about connection conditions are indicated on
the rating plate and in the operating instructions.
3.1
SINAMICS G120D CU240D-2 Inverter
Overview
The SINAMICS G120D is a converter for controlling the speed of three-phase motors. The
converter consists of two parts, the Control Unit (CU) and the Power Module (PM).
Table 3- 1
CU240D-2 Control Units
Designation
CU240D-2 DP
CU240D-2 DP-F
CU240D-2 PN
CU240D-2 PN-F
CU240D-2 PN-F PP
CU240D-2 PN-F FO
Converter with control units CU240D-2
Operating Instructions, 07/2016, FW V4.7 SP6, A5E34262100B AD
Interface
PROFIBUS
PROFIBUS
PROFINET, EtherNet/IP
PROFINET, EtherNet/IP
PROFINET, EtherNet/IP
Push-Pull connections
PROFINET, EtherNet/IP
Fibre optic connections
Encoder type
Article number
HTL Encoder
6SL3544-0FB20-1PA0
HTL Encoder
6SL3544-0FB21-1PA0
HTL Encoder
6SL3544-0FB20-1FA0
HTL Encoder
6SL3544-0FB21-1FA0
HTL Encoder
6SL3544-0FB21-1FB0
HTL Encoder
6SL3544-0FB21-1FC0
3
25