Siemens SINAMICS S120 Function Manual page 383

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Error code in Gn_XIST2
Table 10-20 Error code in Gn_XIST2
n_XIST2
Meaning
1
Encoder error
2
Zero marker monitoring
3
Abort parking sensor
4
Abort find reference
marker
5
Abort, retrieve reference
value
6
Abort flying measurement •
7
Abort get measured value •
8
Abort absolute value
transmission on
3841
Function not supported
Encoder 2 status word (G2_STW)
● See G1_STW (table 4-20)
Encoder 2 actual position value 1 (G2_XACT1)
● See G1_XIST1
Encoder 2 actual position value 2 (G2_XACT2)
● See G1_XIST2
Encoder 3 status word (G3_STW)
● See G1_STW (table 4-20)
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
One or more existing encoder faults.
Detailed information in accordance with drive messages.
Parking drive object already selected.
A fault exists (Gn_ZSW.15 = 1)
Encoder has no zero marker (reference marker)
Reference marker 2, 3 or 4 is requested
Switchover to "Measurement on-the-fly" during search for reference marker
Command "Read value x" set during search for reference marker
Inconsistent position measured value with distance-coded reference markers.
More than four values requested
No value requested
Requested value not available
No probe configured p0488, p0489
Switch over to "reference mark search" during flying measurement
Command "Read value x" set during flying measurement
More than one value requested
No value requested.
Requested value not available
Parking encoder active
Parking drive object active
Absolute encoder not available
Alarm bit absolute value protocol set
Communication PROFIBUS DP/PROFINET IO
10.1 Communications according to PROFIdrive
Possible causes / description