Communication PROFIBUS DP/PROFINET IO
10.1 Communications according to PROFIdrive
Bit
Meaning
12
Reserved
13
External block change
14
Reserved
15
Reserved
CTW2 (control word 2)
See function diagram [2444]
Table 10-6
Description of CTW2 (control word 2)
Bit
Meaning
0
Drive data set selection DDS bit 0
1
Drive data set selection DDS bit 1
2
Drive data set selection DDS bit 2
3
Drive data set selection DDS bit 3
4
Drive data set selection DDS bit 4
5...6
Reserved
7
Parking axis
8
Travel to fixed endstop
9
Reserved
10
Reserved
11
Motor switchover
12
Drive unit sign-of-life bit 0
13
Drive unit sign-of-life bit 1
14
Drive unit sign-of-life bit 2
15
Drive unit sign-of-life bit 3
E_CTW1 (control word for INFEED)
See function diagram [8920]
358
Comments
-
-
0/1
External set change is initiated
0
No effect
-
-
-
-
Comments
-
Drive data set selection
(5 bit counter)
-
-
-
-
-
-
1
Request parking axis (handshake with ZSW2 bit
7)
0
No request
1
Select "Travel to fixed stop"
The signal must be set before the fixed stop is
reached.
1/0
Deselect "Travel to fixed stop"
The signal must be set before the fixed stop is
reached
-
-
-
-
0/1
Motor switchover complete
0
No effect
-
User data integrity (4-bit counter)
-
-
-
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
BICO
-
BI: 2632
-
-
BICO
BI: p0820[0]
BI: p0821[0]
BI: p0822[0]
BI: p0823[0]
BI: p0824[0]
-
BI: p0897
BI: p1545
-
-
BI: p0828[0]
CI: p2045
Drive Functions