Table 10-24 Description of CU_ZSW (status word for Control Unit)
Bit
Meaning
0...2
Reserved
3
Fault active
4...6
Reserved
7
Alarm present
8
SYNC
9...11 Reserved
12
Drive unit sign-of-life bit 0
13
Drive unit sign-of-life bit 1
14
Drive unit sign-of-life bit 2
15
Drive unit sign-of-life bit 3
E_DIGITAL (digital inputs)
See function diagram [2459].
Table 10-25 Description of E_DIGITAL (digital inputs)
Bit
Meaning
0
Digital input/output 8
(DI/DO = 8)
1
Digital input/output 9
(DI/DO = 9)
2
Digital input/output 10
(DI/DO = 10)
3
Digital input/output 11
(DI/DO = 11)
4
Digital input/output 12
(DI/DO = 12)
5
Digital input/output 13
(DI/DO = 13)
6
Digital input/output 14
(DI/DO = 14)
7
Digital input/output 15
(DI/DO = 15)
8
Digital input 0 (DI 0)
9
Digital input 1 (DI 1)
10
Digital input 2 (DI 2)
11
Digital input 3 (DI 3)
12
Digital input 4 (DI 4)
13
Digital input 5 (DI 5)
14
Digital input 6 (DI 6)
15
Digital input 7 (DI 7)
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
1
Fault active
0
No fault present
1
Alarm present
0
No alarm present
Slave sign of life
DI/DO 8 on the Control Unit must be parameterized as an input
(p0728.8 = 0).
DI/DO 9 on the Control Unit must be parameterized as an input
(p0728.9 = 0).
DI/DO 10 on the Control Unit must be parameterized as an input
(p0728.10 = 0).
DI/DO 11 on the Control Unit must be parameterized as an input
(p0728.11 = 0).
DI/DO 12 on the Control Unit must be parameterized as an input
(p0728.12 = 0).
DI/DO 13 on the Control Unit must be parameterized as an input
(p0728.13 = 0).
DI/DO 14 on the Control Unit must be parameterized as an input
(p0728.14 = 0).
DI/DO 15 on the Control Unit must be parameterized as an input
(p0728.15 = 0).
Digital input DI 0 on the Control Unit
Digital input DI 1 on the Control Unit
Digital input DI 2 on the Control Unit
Digital input DI 3 on the Control Unit
Digital input DI 4 on the Control Unit
Digital input DI 5 on the Control Unit
Digital input DI 6 on the Control Unit
Digital input DI 7 on the Control Unit
Communication PROFIBUS DP/PROFINET IO
10.1 Communications according to PROFIdrive
Remarks
Remarks
BICO
BO: r2139.3
BO: 2139.7
BO: r0899.8
Implicitly
interconnec-
ted
BICO
BO: p0722.8
BO: p0722.9
BO:
p0722.10
BO:
p0722.11
BO:
p0722.12
BO:
p0722.13
BO:
p0722.14
BO:
p0722.15
BO: r0722.0
BO: r0722.1
BO: r0722.2
BO: r0722.3
BO: r0722.4
BO: r0722.5
BO: r0722.6
BO: r0722.7