Siemens SINAMICS S120 Function Manual page 396

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Communication PROFIBUS DP/PROFINET IO
10.1 Communications according to PROFIdrive
Field
No. of values
Error values
Values
Error values in DPV1 parameter responses
Table 10-27 Error values in DPV1 parameter responses
Error
value
0x00
Illegal parameter number
0x01
Parameter value cannot be changed
0x02
Lower or upper value limit exceeded
0x03
Invalid subindex
0x04
No array
0x05
Wrong data type
0x06
Illegal set operation (only reset
allowed)
0x07
Description element cannot be
changed
0x09
No description data
0x0B
No operating priority
0x0F
No text array exists
0x11
Request cannot be executed due to
operating status
0x14
Illegal value
396
Data type
The format and number specify the adjoining space containing values in the telegram.
Data types in conformity with PROFIdrive Profile shall be preferred for write access. Bytes,
words and double words are also possible as a substitute.
Unsigned8
Specifies the number of subsequent values.
Unsigned16
The error values in the event of a negative response.
If the values make up an odd number of bytes, a zero byte is appended. This ensures the
integrity of the word structure of the telegram.
Unsigned16
The values of the parameter for read or write access.
If the values make up an odd number of bytes, a zero byte is appended. This ensures the
integrity of the word structure of the telegram.
Meaning
Values
0x00 ... 0xEA
0x0000 ... 0x00FF
0x0000 ... 0x00FF
Comment
Access to a parameter which does not exist.
Modification access to a parameter value which cannot be
changed.
Modification access with value outside value limits.
Access to a subindex which does not exist.
Access with subindex to an unindexed parameter.
Modification access with a value which does not match the
data type of the parameter.
Modification access with a value not equal to 0 in a case
where this is not allowed.
Modification access to a description element which cannot
be changed.
Access to a description which does not exist (the
parameter value exists).
Modification access with no operating priority.
Access to a text array which does not exist (the parameter
value exists).
Access is not possible temporarily for unspecified reasons. –
Modification access with a value which is within the limits
but which is illegal for other permanent reasons
(parameter with defined individual values).
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
Comment
No. 0 ... 234
Limited by DPV1 telegram length
Meaning of error value
--> see table 4-29
Additional
Subindex
Subindex
Subindex
Subindex
Subindex
Subindex