p0112
p0115[0]
2: Low
250
3: Standard
250
4: High
250
5: xHigh
-
Table 12-24 For Basic Infeed Booksize, the sampling time is set using p0112
p0112
p0115[0]
1: xLow
-
2: Low
-
3: Standard
-
4: High
250
5: xHigh
-
Table 12-25 For Basic Infeed Chassis, the sampling time is set using p0112
p0112
p0115[0]
1: xLow
2000
2: Low
2000
3: Standard
2000
4: High
250
5: xHigh
-
Table 12-26 For Servo, the sampling time is set using p0112
p0112
p0115[0]
1: xLow
250
2: Low
125
3: Standard
125
4: High
62.5
5: xHigh
-
Table 12-27 For Vector, the sampling time is set using p0112 (p0112 = 1 not for p0092 = 1 and not for PM340)
p0112
p0115[0]
1: xLow
400
2: Low
250
3: Standard
250
4: High
250
5: xHigh
250
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
p0115[1]
p0115[2]
-
-
-
-
-
-
-
-
p0115[1]
p0115[2]
-
-
-
-
-
-
-
-
-
-
p0115[1]
p0115[2]
-
-
-
-
-
-
-
-
-
-
p0115[1]
p0115[2]
250
250
250
250
125
125
62.5
62.5
-
-
p0115[1]
p0115[2]
1600
1600
1000
2000
1000
1000
500
1000
250
1000
Basic information about the drive system
p0115[3]
p0115[4]
2000
-
2000
-
1000
-
-
-
p0115[3]
p0115[4]
-
-
-
-
-
-
2000
-
-
-
p0115[3]
p0115[4]
2000
-
2000
-
2000
-
2000
-
-
-
p0115[3]
p0115[4]
4000
2000
4000
2000
4000
1000
1000
1000
-
-
p0115[3]
p0115[4]
3200
3200
1000
2000
1000
2000
500
1000
250
1000
12.12 System sampling times
p0115[5]
p0115[6]
-
-
-
-
-
-
-
-
p0115[5]
p0115[6]
-
-
-
-
-
-
-
-
-
-
p0115[5]
p0115[6]
-
-
-
-
-
-
-
-
-
-
p0115[5]
p0115[6]
8000
4000
8000
4000
4000
4000
2000
1000
-
-
p0115[5]
p0115[6]
3200
3200
4000
4000
4000
4000
2000
2000
2000
1000
525