Siemens SINAMICS S120 Function Manual page 357

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Bit
Meaning
1
OFF2
Note:
Control signal OFF2 is generated by ANDing BI: p0844 and BI: p0845.
2
OFF3
Note:
Control signal OFF3 is generated by ANDing BI: p0848 and BI: p0849.
3
Enable operation
4
Reject traversing task
5
Intermediate stop
6
Activate traversing task
Note:
The interconnection p2649 = 0 is also made.
7
Acknowledge fault
8
Jog 1
9
Jog 2
10
Master ctrl by PLC
Note:
This bit should not be set to "1" until the PROFIdrive has returned an appropriate status via ZSW1.9 = "1".
11
Start referencing
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
Communication PROFIBUS DP/PROFINET IO
10.1 Communications according to PROFIdrive
Comments
1
No OFF2
Enable possible
0
OFF2
Immediate pulse cancellation and power-on
inhibit
1
No OFF3
Enable possible
0
Emergency stop (OFF3)
Braking with OFF3 ramp p1135, then pulse
cancellation and power-on inhibit.
1
Enable operation
Pulse enable possible
0
Disable operation
Cancel pulses
1
Do not reject traversing task
0
Reject traversing task
1
No intermediate stop
0
Intermediate stop
0/1
Enable setpoint
0
No effect
0/1
Acknowledge fault
0
No effect
1
Jog 1 ON
See also the SINAMICS S List Manual, function
diagram 3610
0
No effect
1
Jog 2 ON
See also the SINAMICS S List Manual, function
diagram 3610
0
No effect
1
Control via PLC
This signal must be set so that the process data
transferred via PROFIdrive is accepted and
becomes effective.
0
No control via PLC
Process data transferred via PROFIdrive is
rejected - i.e. it is assumed to be zero.
1
Start referencing
0
Stop reference
BICO
BI: p0844
BI: p0848
BI: p0852
BI: p1140
BI: p2640
BI: p2631,
p2650
BI: p2103
BI: p2589
BI: p2590
BI: p0854
BI: p2595
357