Lucent Technologies MERLIN LEGEND System Manager's Manual page 373

Communications system release 5.0
Hide thumbs Also See for MERLIN LEGEND:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 5.0
System Manager's Guide 555-650-118
A
Customer Support Information
Toll Fraud Prevention
Customers should also take advantage of Lucent Technologies monitoring
services and devices, such as the NetPROTECT
fraud-detection services, CAS with HackerTracker
with Watchdog. Call 1 800 638-7233 to get more information on these
Lucent Technologies fraud detection services and products.
Security Risks Associated with Transferring
through Voice Messaging Systems
Toll fraud hackers try to dial into a voice mailbox and then execute a transfer by
dialing
*T
Selection or a pooled facility code) followed by the appropriate digit string to either
direct dial or access a network operator to complete the call.
NOTE:
In Release 3.1 and later systems, all extensions are initially and by default
restricted from dial access to pools. In order for an extension to use a pool
to access an outside line/trunk, this restriction must be removed.
Preventive Measures
Take the following preventive measures to limit the risk of unauthorized transfers
by hackers:
Outward restrict all MERLIN LEGEND Communications System voice mail
port extension numbers. This denies access to facilities (lines/trunks). In
Release 3.1 and later systems, voice mail ports are by default outward
restricted.
As an additional security step, network dialing for all extensions, including
voice mail port extensions, should be processed through ARS using dial
access code
!
. The hacker then dials an access code (either
.
9
SECURITYlALERT:
The MERLIN LEGEND Communications System ships with ARS
activated with all extensions set to Facility Restriction Level 3,
allowing all international calling. To prevent toll fraud, ARS Facility
Restriction Levels (FRLs) should be established using:
FRL 0 for restriction to internal dialing only
FRL 2 for restriction to local network calling only
FRL 3 for restriction to domestic ong-distance (excluding
area code 809 for the Dominican Republic as this is part of
the North American Numbering Plan, unless 809 is required)
RL 4 for international calling
In Release 3.1 and later systems, default local and default toll tables
are factory-assigned an FRL of 2. This simplifies the task of
SM
family of
®
, and CAT Terminal
1
for Automatic Route
9
1
Issue 1
June 1997
Page A-11

Advertisement

Table of Contents
loading

Table of Contents