4. MECHANICAL SYSTEM
5. Cleaning the Pre-Cleaning Exposure Cover
1) Remove the drum unit. (See p. 4-64.)
2) Remove the photosensitive unit. (See p. 4-66.)
3) Remove the screw q, and remove the mounting
plate w.
w
Rear
Figure 4-512
4) Slide out the pre-cleaning exposure cover e,
and clean it.
Rear
Figure 4-513
5) Push in the pre-exposure cover, and install the
mounting plate and the photosensitive drum;
then, install the drum unit.
4-68
COPYRIGHT © 1996 CANON INC.
6. Cleaning the Upper Transfer Guide
1) Remove the drum unit. (See p. 4-64.)
2) Remove the screw q (front, rear), and remove
the positioning bush w (front, rear).
q
3) Holding the right side of the upper transfer guide
e, turn it in the direction of the arrow.
e
CANON NP6085 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
w
q
Front
Figure 4-514
e
Front
Figure 4-515