3. OPERATIONS AND TIMING
Item
Description
CALL SW
Use it to store copy-
ing modes current
at time of a press
on the Copy Start
key. (up to 5)
OHP_TEMP
Use it to select a fix-
ing temperature for
transparencies.
VDT_SW
Use it to select a
target value of dark
area potential (V
for use in primary
cyrrent control.
DOC_F_SW
Use it to select a
stream reading
mode.
AL_DISP
Use it to select
when the message
"The cleaning web
needs to be
replaced" is shown.
3-240
COPYRIGHT © 1996 CANON INC.
5 USER OPTION
CALLSW
:
0 (0:0FF,1:ON)
OHP_TEMP :
0 (0:0FF,1:ON)
VDT_SW
:
0 (0 ~ 4)
DOC_F_SW :
0 (0:0FF,1:ON)
AL_DISP
:
0 (0:0FF,1:ON)
Screen 5-5
0: OFF (default)
1: ON (A call key will be indicat-
ed on the message display;
the user may press the key
to select one from the most
recent five.)
0: OFF (default)
1: ON (20Þ lower thean normal
for temperature control)
0: Standard voltage (default)
1: target potential at -20 V of
)
standard voltage.
D
2: target potential at -10 V of
standard voltage.
3: target potential at +10 V of
standard voltage.
4: target potential at +20 V of
standard voltage.
0: OFF (default)
1: ON
0: OFF (default; Indicates the
message at the service
mode.)
1: ON (Indicates the message
always.)
CANON NP6085 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
Settings
Remarks
Enter '0' or '1' on the numeric
keypad.
See p. 3-51.