2. C.F.F. Position
The No. 1 through No. 3 mirrors are not used
when making copies with the optional C.F.F.
As such, the scanner is moved farther left than
the normal home position, called the C.F.F. posi-
tion.
C.F.F. shutter
COPYRIGHT © 1996 CANON INC.
C.F.F. optical
Standard white plate
path (hole)
No. 2
mirror
No. 1 mirror
No. 3 mirror
Figure 3-208
CANON NP6085 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
3. OPERATIONS AND TIMING
The C.F.F. position is detected by the scanner
C.F.F. position sensor (Q6), and the scanner is
fixed in the C.F.F. position after Q6 has recognized
that the scanner has reached the position. (See
Figure 3-208.)
Copyboard glass
Scanning lamp
To No. 4 mirror