1. GENERAL INTRODUCTION
c. Timer Settings
Item
Auto clear time
Use it to set the auto clear time between 10 sec and 9 min in
1-sec increments. Setting it to 0 min disables the auto clear
function.
Auto power-off
Use it to set the auto power-off time between 10 min and 2 hr
time
as follows:
You may disable the auto power-off function in service mode.
Day timer
Use it to set the time at which the auto power-off mechanism
settings
is activated by day of week.
Date/ time
Use it to set the date and time of the built-in clock.
settings
d. Adjustment/Cleaning
Item
Zoom
Use it to adjust the vertical and horizontal reproduction ratios
fine adjustment
for copying at 100% (1% max.).
Feeder cleaning
Use it to execute simple cleaning of the RDF's separation
belt.
Set ten blank sheets of copy paper, and press the Start key to
start cleaning.
Wire cleaning
Press the Start key to execute automatic cleaning of the pri-
mary charging wire, pre-transfer changing wire, transfer char-
ging wire, and separation charging wire.
1-26
COPYRIGHT © 1996 CANON INC.
Description
from 10 min to 1 hr, in 10-min increments
from 1 hr to 2 hr, in 1-hr increments
Description
Adjustment width: -1.0 to +1.0
Adjustment unit: 0.2%
CANON NP6085 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)