F. Adjustment Mode (
•
Press the
/
key to select the appropriate screen.
•
Press the item to select. (The selected item will be highlighted.)
•
Enter the appropriate value using the numeric keypad or the
the value.
•
Use the
key to enter a negative value.
– / +
Item
DRUM_SEL
Use it to set the sensitivity to
suit the photosensitive drum.
ATM
Use it to set the operating envi-
ronment in relation to the
atmospheric pressure. (A high-
er setting will lower the target
potential of potential control. A
low pressure tends to cause
leakage, requiring lowering the
target potential for potential
control.)
BRAKE_SC
Use it to adjust the braking for when
the scanner is moving in reverse.
LE_BLANK
Use it to adjust the margin
along the leading edge width.
(ON period of blank exposure lamp)
MULT_SZ
Use it to correct the input data
of the multifeeder paper width
detecting variable resistor.
COPYRIGHT © 1996 CANON INC.
)
3
3 ADJUST
DRUM_SEL :
14
ATM
:
1
BRAKE_SC :
25
LE_BLANK
:
+15
MULT_SZ
:
-5
Screen 3-1
Description
CANON NP6085 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
/
key; then, press the
14
1
25
+15
- +
-5
OK
Settings
1-30
After replacing the photosensitive drum,
enter the setting recorded on the sheet
that comes with the drum.
A press on the
potential control. (Only if PO.CONT is ON.)
0-3
0: For low density
(Select if the copies are too light.)
1: 1 to 0.70 atm
(Select if the elevation is up to
about 3,000 m.)
2: 0.70 to 0.65 atm
(Select if the elevation is between
3,000 and 3,500 m.)
3: 0.65 to 0.60 atm
(Select if the elevation is between
about 3,500 and 4,500 m.)
2-40
A higher setting will increase the brak-
ing on the scanner.
-128-
A higher setting will increase the lead-
+127
ing edge width. (unit: 0.1 mm)
-128-
A higher setting will increase the cor-
+127
rection data, thereby increasing the
value of detection width.
3. OPERATIONS AND TIMING
to store
OK
Remarks
key will execute
OK