Canon NP6085 Service Manual page 91

Table of Contents

Advertisement

b. Lens Movement and Copying Operation
The microprocessor master and slave (Q115)
retain the positions of the lens in relation to vari-
ous combinations of different original sizes and
copy sizes in memory.
When a change is initiated in the selected
reproduction ratio, it immediately sends drive
pulses for the X motor (M9)/Y motor (M10), there-
by changing the position of the lens (period II in
Figure 3-205).
Cam plate
Q2 Signal plate
Lens Y home
position sensor
(Q2)
COPYRIGHT © 1996 CANON INC.
Lens stage
Lens
DC controller PCB
Figure 3-206
CANON NP6085 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
The lens Y motor (M10) moves once again
when the Copy Start key is pressed and the orig-
inal size and the copy size have been established
(III in Figure 3-205).
Q3 Signal plate
Lens Y home
position sensor
(Q3)
Cam groove
Y direction
Lens Y motor
(M10)
3. OPERATIONS AND TIMING
Lens X motor
(M9)
3-33