8. Down Sequence
The NP6085 is provided with a down
sequence to ensure proper fixing in continuous
copying under low-temperature conditions.
The copying speed is reduced so that the dis-
tance between sheets will be longer when the
thermistor (TH1) of the fixing roller detects any of
the following surface temperatures for the fixing
roller.
The control mode may be any of three as
selected in service mode (
Setting 0 (initial setting)
Start
Copies/min
tempera-
ture
71
155 (˚C)
66
150
Stop
145
COPYRIGHT © 1996 CANON INC.
; FIX-TEMP).
5
Setting 1
Normal
Start
speed return
tempera-
temperature
ture
160 (˚C)
160 (˚C)
160
155
160
150
Table 3-406
CANON NP6085 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
Setting 2
Normal
Start
speed return
tempera-
temperature
ture
165 (˚C)
150 (˚C)
165
145
165
140
3. OPERATIONS AND TIMING
Setting 3
Normal
Start
speed return
tempera-
temperature
ture
155 (˚C)
165 (˚C)
155
160
155
155
Normal
speed return
temperature
170 (˚C)
170
170
3-127