Troubleshooting
SIP Transitions Repeatedly From On to Off
Possible Problem
SIP does not go beyond the
bootup stage
SIP FPGA is not up to date
SIP Is Deactivated
Possible Problem
SPA is not fully seated in the
SIP
SPA is not supported on the
SIP
SPA is not at the minimum
hardware revision level
SPA is misconfigured
Cisco 7600 Series Router SIP, SSC, and SPA Hardware Installation Guide
7-2
Observations and Comments
SIP STATUS LED transitions
continue and alternates green,
amber, or off
During SIP initalization, the
need to update the FPGA is
automatically detected
Observations and Comments
Output of the show diag slot
command
SPA STATUS LED is off
Error message indicating the
SPA is not supported
Output of the show diag slot
command
SIP STATUS LED is off
Error message indicating the
SPA is not at the minimum
FPGA revision level
Output of the show hw-module
subslot fpd command
Output of the show diag slot
command
SPA STATUS LED is off
Chapter 7
Solutions
Follow the recommended action for the displayed error
message.
Follow the system prompts to update the FPGA image.
If the SIP is cycling because of an FPD problem, the most
likely cause is a FPD failure or that the FPD package file is
not present.
For more information about performing FPD upgrades,
refer to the "Upgrading Field-Programmable Devices"
chapter in the Cisco 7600 Series Router SIP, SSC, and SPA
Software Configuration Guide.
Solutions
Follow this procedure:
Remove the SPA from the SIP.
Inspect the SIP and the SPA. Verify there are no bent
pins or parts and that there is nothing lodged in the two
devices that could prevent a good connection.
Insert the SPA in the SIP by sliding the SPA all the way
into the SIP until the SPA is firmly seated in the SPA
interface connector. When fully seated in the SIP, the
SPA might be slightly behind the SIP faceplate.
Install a SPA supported on the SIP.
Follow the FPD upgrade process to update the FPGA.
For more information about performing FPD upgrades,
refer to the "Upgrading Field-Programmable Devices"
chapter in the Cisco 7600 Series Router SIP, SSC, and SPA
Software Configuration Guide.
Refer to the configuration section of the specific SPA
installation and configuration guide, or use the Cisco IOS
software configuration documentation listed in the
"Obtaining Documentation, Obtaining Support, and
Security Guidelines" section on page
Troubleshooting the Installation
xv.
OL-5052-14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7600 sip-600Cisco 7600 ssc-4007600 sip-2007600 sip-400

Table of Contents