2-Port And 4-Port Clear Channel T3/E3 Spa Leds; 2-Port And 4-Port Clear Channel T3/E3 Spa Interface Specifications - Cisco 7600 SIP 200 - SPA Interface Processor 200 Hardware Installation Manual

7600 series sip, ssc, and spa hardware installation guide
Table of Contents

Advertisement

2-Port and 4-Port Clear Channel T3/E3 SPA Overview

2-Port and 4-Port Clear Channel T3/E3 SPA LEDs

The 2-Port and 4-Port Clear Channel T3/E3 SPA has three types of LEDs: two LEDs for each port on
the SPA, and one STATUS LED, as shown in
Figure 3-2
1
2
3
Table 3-4
Table 3-4
LED Label
C/A
A/L
STATUS

2-Port and 4-Port Clear Channel T3/E3 SPA Interface Specifications

The framer processes incoming and outgoing T3 (cbit, m13/m23, and unframe) and E3 (g751, g832, and
unframe) frames. The framer operates at T3/E3 line rates (44.736 /34.368 Mbps) depending on the mode
in which it is configured.
Packet data is transported with a user-configurable encapsulation (such as Point-to-Point Protocol [PPP]
or High-Level Data Link Control [HDLC]), and is mapped to T3 and E3 frames. The encapsulations add
transport overhead to the packet of data frames before transporting, and are stripped when a packet is
transported to the far end.
Cisco 7600 Series Router SIP, SSC, and SPA Hardware Installation Guide
3-8
4-Port Clear Channel T3/E3 SPA Faceplate
2
1
3
4
C/A (Carrier/Alarm) LED
A/L (Active Loopback) LED
TX (Transmit) connector
describes the 2-Port and 4-Port Clear Channel T3/E3 SPA LEDs.
2-Port and 4-Port Clear Channel T3/E3 SPA LEDs
Color
Off
Green
Amber
Off
Green
Amber
Off
Green
Amber
Chapter 3
Overview: Cisco 7600 Series Router Shared Port Adapters
Figure
3-2.
4
RX (Receive) connector
5
STATUS LED
State
Meaning
Off
Port is not enabled by software.
On
Port is enabled by software, and there is a valid E3 or T3
signal without any alarms.
On
Port is enabled by software, and there is at least one alarm.
Off
Port is not enabled by software.
On
Port is enabled by software, and loopback is off.
On
Port is enabled by software, and loopback is on.
Off
SPA power is off.
On
SPA is ready and operational.
On
SPA power is on and good, and the SPA is being configured.
SPA-4XT3/E3
5
OL-5052-14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7600 sip-600Cisco 7600 ssc-4007600 sip-2007600 sip-400

Table of Contents