Troubleshooting the Installation

Troubleshooting Line Card Power Issues
Table 7-1
Problem
If a line card fails to operate or power up
Miscellaneous Line Card Issues
Table 7-2
OL-5052-14
provides solutions for troubleshooting line card issues.
Table 7-1
provides solutions for troubleshooting line card issues.
Cisco 7600 Series Router SIP, SSC, and SPA Hardware Installation Guide
Troubleshooting Line Card Power Issues
Solution
1.
Ensure that the card is seated firmly in the
slot.
Ensure that you have placed the gold edge of
2.
the PCB in the guide rails of the chassis. This
prevents damage to the connector placed at
the rear side the board.
Check whether the ejector levers are latched
3.
and that the captive screws are fastened
properly. If you're uncertain, unlatch the
levers, loosen the screws, and attempt to reset
the supervisor again.
Examine the power supply to see whether the
4.
complete chassis is receiving power.
Use the show power command to confirm if
5.
the chassis has sufficient power to initiate the
new inserted line card.
Use the status LED on the line card to verify
6.
the correct installation of the card. If the card
is installed correctly, the Status LED turns
green.
Ensure that you have installed the line cards
7.
in their designated slots.
Note
All line cards can be inserted in all the
slots of chassis; however 7613 chassis has
exceptions. Dual fabric channel line cards
such as (ES20 and ES+ cards) can be
inserted only in 9 to13 slots of 7613
chassis.