Vdsl Configuration - Accton Technology VS4512DC Management Manual

Vdsl switch (with ac power connector) supporting 12 vdsl lines, with 2 slots for optional 1000base-sx, 1000base-lx, 1000base-t or 1000base-x gbic uplink modules
Table of Contents

Advertisement

Configuring the Switch

VDSL Configuration

You can configure and display communication parameters for VDSL and Ethernet
ports on the switch and connected CPEs.
VDSL Global Configuration
This Web page assigns the same profile to each VDSL switch port. Details of these
profiles are given in the table below.
Profile Name
Default
A1-02OAG-R1
A2-02OAG-R1
A3-01OAG-R1
A4-01OAG-R1
S1-03OAG-R1
S2-03OAG-R1
S3-00OAG-R1
S1-16-16
S2-16-16A
A1-34-11
A2-34-11A
A3-25-3
A4-45-5
A5-50-7
A6-22-3A
A7-40-5A
A8-46-7A
TLAN
Max-Rate
Notes: 1. The VDSL Intelligent Switch uses Ethernet in the First Mile (EFM), a
VDSL-based technology.
2. A suffix of "A" in the profile name (e.g., S2-16-16A) indicate that this profile is
for both VDSL and ADSL lines in a bundle. Profiles without a suffix of "A" in
the profile name (e.g., S1-16-16) are for VDSL lines only.
3. The following profiles are recommended for use with this switch: S1-16-16,
S2-16-16A, A1-34-11, and A2-34-11A.
3-56
ProfileType
Public
Public
Public
Public
Public
Public
Public
Public
Private
Private
Private
Private
Private
Private
Private
Private
Private
Private
Private
Private
Downstream Rate
(Mbps)
1.20
7.56
10.80
17.28
25.92
7.56
10.80
17.28
16.74
16.74
33.75
33.75
25.38
44.55
50.49
22.55
40.91
46.44
17.01
71.28
Upstream Rate
(Mbps)
1.40
2.43
2.43
3.78
4.72
7.56
10.40
16.47
16.20
16.20
11.34
11.34
3.24
5.13
7.29
3.24
5.13
7.29
5.40
40.50

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vs4512Vdsl switch-vs4512Vdsl switch-vs4512dc

Table of Contents