logging sendmail host

This command specifies SMTP servers that will be sent alert messages. Use the no
form to remove an SMTP server.
Syntax
[no] logging sendmail host ip_address
ip_address - IP address of an SMTP server that will be sent alert
messages for event handling.
Default Setting
None
Command Mode
Global Configuration
Command Usage
• You can specify up to three SMTP servers for event handing. However, you
must enter a separate command to specify each server.
• To send email alerts, the switch first opens a connection, sends all the email
alerts waiting in the queue one by one, and finally closes the connection.
• To open a connection, the switch first selects the server that successfully sent
mail during the last connection, or the first server configured by this command.
If it fails to send mail, the switch selects the next server in the list and tries to
send mail again. If it still fails, the system will repeat the process at a periodic
interval. (A trap will be triggered if the switch cannot successfully open a
connection.)
Example
Console(config)#logging sendmail host 192.168.1.19
Console(config)#

logging sendmail level

This command sets the severity threshold used to trigger alert messages.
Syntax
logging sendmail level [level]
level - One of the system message levels (page 4-36). Messages sent
include the selected level down to level 0. (Range: 0-7; Default: 7)
Default Setting
Level 7
Command Mode
Global Configuration
System Management Commands
4-41