CLI –The following examples show how VDSL link current values are displayed in
the CLI.
Examples
The following example displays VDSL link current values on VDSL switch port 2.
Console#show controller efm Ethernet 1/2 actual dsrserrs
Downstream Reed-Solomon errors: 0
Console#show controller efm Ethernet 1/2 actual link
Link status: Down
Console#show controller efm Ethernet 1/2 actual rxpower
Local receive power: 26.00 dBm/Hz
Console#show controller lre Ethernet 1/2 actual snr
SNR: 27.00 dB
Console#show controller efm Ethernet 1/2 actual txpower
Remote transmit power: -89.70 dBm/Hz
Console#
The following example displays link status, signal-to-noise ratios, Reed-Solomon
errors, interleaver parameters and PBO status on VDSL switch port 1.
Console#show controllers efm status link Ethernet 1/1
Interface
Link
-------------
----
Ethernet 1/1
Up
Console#
This command displays the downstream and upstream rates of the VDSL port 1.
Console#show controller efm Ethernet 1/1 admin usrate
Upstream rate: 12.50 Mbps
Console#show controller efm Ethernet 1/1 admin dsrate
Downstream rate: 12.50 Mbps
Console#
SNR (dB)
DS1
DS2
US1
--------------------
43.0 35.0 45.0 43.0
RS Errs
US2
DS.M DS.I US.M US.I PBO
--------
------------------- ---
0
VDSL Configuration
4-111
4-114
Interleaver