Efm Interleave - Accton Technology VS4512DC Management Manual

Vdsl switch (with ac power connector) supporting 12 vdsl lines, with 2 slots for optional 1000base-sx, 1000base-lx, 1000base-t or 1000base-x gbic uplink modules
Table of Contents

Advertisement

Command Line Interface

efm interleave

This command sets the interleave parameters for the selected VDSL port.
Syntax
efm interleave [downstream M value] [upstream M value]
[downstream I value] [upstream I value]
no efm interleave
M value – M is the interleaving depth index. Range: 0-64
I value – I is the interleaving block length. Range: 4 or 8
Default Setting
M – The interleaving depth index.
Upstream default value: 8, Downstream default value: 16
I – The interleaving block length.
Upstream default value: 8, Downstream default value: 8
Command Mode
Interface Configuration
Command Usage
Interleaving improves Reed Solomon error correction when there is pulse
noise. A greater degree of interleaving will provide more protection against
pulse noise but will increase transmission delay and reduce the effective
bandwidth of the link. The degree of interleaving can be increased by
increasing M or I.
Example
The following example configures VDSL port 1 with:
M - downstream value: 16, Upstream value: 8
I - downstream value: 8, Upstream value: 8
Console#config
Console(config)#interface ethernet 1/1
Console(config-if)#efm interleave 16 8 8 8
Console(config-if)#end
Console#show controllers efm status link Ethernet 1/1
Interface
Link
------------- ---- -------------------- -------- ------------------- ---
Ethernet 1/1
Up
Console#
Related Commands
efm noise-margin (4-107)
show controllers efm status (4-114)
4-106
SNR (dB)
DS1
DS2
US1
US2
43.0 35.0 45.0 43.0
RS Errs
Interleaver
DS.M DS.I US.M US.I PBO
0
16
8
8
8
on

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vs4512Vdsl switch-vs4512Vdsl switch-vs4512dc

Table of Contents