Hot-Plug Hard-Drive Backplane

The following replacement procedure applies only to sleds with front-access
2.5-inch hot-plug hard-drives.

Removing the Hot-Plug Hard-Drive Backplane

CAUTION:
Many repairs may only be done by a certified service technician. You
should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized is not covered by
warranty. Read and follow the safety instructions that came with the product.
1 Remove the sled from the enclosure. See "Removing a Sled" on page 141.
2 Open the sled. See "Removing the Front and Back Sled Covers" on
page 161.
3 Press the cable-locking tabs and disconnect the SAS data cables from the
hot-plug hard-drive backplane. See Figure 3-28.
4 Press down the cable-locking tab and disconnect the power cable from the
hot-plug hard-drive backplane. See Figure 3-28.
5 Disconnect the SGPIO cable from the hot-plug hard-drive backplane.