7 In the Remote Access Configuration screen, verify the following settings:
Remote Access: Enabled
Serial port number: COM2 as SOL
Serial Port Mode: 115200 8,n,1
Flow Control: None
Redirection After BIOS POST: Always
Terminal Type: ANSI
See "Remote Access Configuration" on page 94 for details. Make sure the
last four options syncs with the host and client.
8 In the Server screen, select BMC LAN Configuration and press <Enter>.
9 In the BMC LAN Configuration screen, verify the following settings:
BMC LAN Port Configuration: Dedicated-NIC
BMC NIC IP Source: DHCP or Static (Use DHCP if your network
servers are using automatic assignment of IP addresses)
IP Address: 192.168.001.003
Subnet Mask: 255.255.255.000
Gateway Address: 000.000.000.000
See "Set BMC LAN Configuration" on page 93 for details. Make sure the
host and client are on the same network
10 Press <Esc> to return to the System Setup screen. Press <Esc> again,
and a message prompts you to save the changes.
To activate console redirection via a shared BMC management port, you must
configure the following settings:
1 Connect the internal BMC cable to the sled. See "Installing the BMC
Management Cable" on page 245.
2 Connect the network cable to the server enclosure's BMC management
port and Ethernet connector. See Figure 1-6 for network cable connection
in shared-NIC mode.
3 Press <F2> immediately after a power-on or reboot to enter System
Setup.
4 In the System Setup screen, select the Server menu and press <Enter>.