Troubleshooting The Enclosure Fan Modules - Dell PowerEdge C8000 Hardware Owner's Manual

Dell poweredge c8220x hardware owner's manual
Hide thumbs Also See for PowerEdge C8000:
Table of Contents

Advertisement

Expansion card
Memory modules
Processors and heat sinks
Cooling shroud
Hard-drives
5 Ensure that all cables are properly connected.
6 Ensure that all components are properly installed and free of damage.
7 If the system fails to start, see "Getting Help" on page 289.

Troubleshooting the Enclosure Fan Modules

CAUTION:
Many repairs may only be done by a certified service technician. You
should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.
NOTE:
The fan modules are hot-swappable. Remove and replace only one fan
module at a time in a server enclosure that is turned on. Operating the system
without all three fan modules for extended periods of time can cause the system to
overheat. Review the following table before you begin to replace the fan modules.
Table 4-1. Fan Module Thermal Behavior Per Sled
Fan Module
BMC (Processor/Memory)/Server Enclosure Temperature Status
Status
OK/OK
Fan module
PID,
normal/OK
Chassis ambient
curve A,
Exhaust
temperature
control curve A
OK/Fail
Fail/OK
PID,
Chassis ambient
curve B,
80% PWM
Exhaust
temperature
control curve A
Fail/Fail
100% PWM
Troubleshooting
265

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge c8220x

Table of Contents