5 Clear the NVRAM.
6 Close the sled. See "Installing the Front and Back Sled Covers" on
page 165 or "Installing the Sled Cover" on page 168.
7 If there is still a problem with the compute sled, remove and reinstall the
sled. See "Installing a Sled" on page 142.
If the problem persists, see "Getting Help" on page 289.
Troubleshooting the System Battery
NOTE:
If the system is turned off for long periods of time (for weeks or months), the
NVRAM may lose its system configuration information. This situation is caused by a
defective battery.
1 Re-enter the time and date through the System Setup program. See
"System Setup Options at Boot" on page 56.
2 Turn off the sled and remove it from the enclosure for at least one hour.
3 Reconnect the sled to the server enclosure and turn on the sled.
4 Enter the System Setup program.
If the date and time are not correct in the System Setup program, replace
the battery. See "Removing the System Battery" on page 252.
CAUTION:
authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety
instructions that came with the product.
If the problem is not resolved by replacing the battery, see "Getting Help"
on page 289.
NOTE:
Some software may cause the system time to speed up or slow down. If the
system seems to operate normally except for the time kept in the System Setup
program, the problem may be caused by software rather than by a defective
battery.
274
Troubleshooting
You should only perform troubleshooting and simple repairs as