System Event Log

Processor Error

Message: "Processor Sensor, IERR error, Processor 1"
Table 1-2. Processor Error
Byte
Field
1
NetFunLun
2
Platform Event Command
3
Generator ID
4
Event Message Format
Version
5
Sensor Type
6
Sensor Number
7
Event Direction Event Type
8
Event Data1
9
Event Data2
10
Event Data3
38
About Your System
Value
Description
10h
02h
01h
Generated by BIOS
04h
Event Message Format Revision.
04h for this specification
07h
Processor
04h
Processor Sensor Number
(depends on platform)
6Fh
Bit 7: 0 = Assert Event Bit 6: 0 =
Event Type Code
AXh
00h: IERR 01h: Thermal Trip
02h: FRB1/BIST Failure
03h: FRB2/Hang in POST Failure
04h: FBR3/Processer
Startup/Initialization Failure
0Ah: Processor Automatically
Throttled
XXh
00h: Processor1
01h: Processor2
02h: Processor3
04h: Processor4
FFh
FFh: Not Present