Memory Ecc - Dell PowerEdge C8000 Hardware Owner's Manual

Dell poweredge c8220x hardware owner's manual
Hide thumbs Also See for PowerEdge C8000:
Table of Contents

Advertisement

Memory Ecc

Message: "Memory Sensor, Correctable ECC error, SBE warning threshold,
CPU1 DIMM_A1"
Table 1-3. Memory ECC
Byte
Field
1
NetFunLun
2
Platform Event Command
3
Generator ID
4
Event Message Format
Version
5
Sensor Type
6
Sensor Number
7
Event Direction Event Type
8
Event Data1
Value
Description
10h
02h
01h
Generated by BIOS
04h
Event Message Format Revision.
04h for this specification
0Ch
Memory
60h
Memory Sensor Number (depend
on platform)
6Fh
Bit 7: 0 = Assert Event
Bit 6: 0 = Event Type Code
AXh
00h: Correctable ECC Error
01h: Uncorrectable ECC Error
03h: Memory Scrub Failed
04h: Memory Device Disabled
08h: Spare
About Your System