Chassis-1005 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference Manual

Brocade fabric os message reference guide v6.2.0 (53-1001157-01, april 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

11

CHASSIS-1005

CHASSIS-1005
Message
<timestamp>, [CHASSIS-1005], <sequence-number>,, ERROR, <system-name>, Diag
attach failed during recovery, disabling slot = <slot number>.
Probable Cause
Indicates that the Diag blade attach has failed during failover or recovery.
Recommended
On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn
Action
command. On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900,
5000, 7500, or AP7600 switch, reboot or power cycle the switch.
Severity
ERROR
78
Fabric OS Message Reference
53-1001157-01