Icpd-1005; Icpd-1006; Icpd-1007; Icpd-1008 - Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference Manual

Brocade fabric os message reference guide v6.2.0 (53-1001157-01, april 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

44

ICPD-1005

Recommended
Enable the iSNS Client service on a single switch in the fabric using the fosConfig command. Refer
Action
to the Fabric OS Command Reference for more information on this command.
Severity
WARNING
ICPD-1005
Message
<timestamp>, [ICPD-1005], <sequence-number>,, WARNING, <system-name>, iSCSI
configuration between local switch (<local domain id>) and peer (<peer domain id>)
is out of sync. iSCSI login is not allowed.
Probable Cause
Indicates that iSCSI switches in the fabric have different configurations in AUTH, VT, or DD.
Recommended
Synchronize the configuration in the fabric using the iscsiCfg command. Refer to the Fabric OS
Action
Command Reference for more information on this command.
Severity
WARNING

ICPD-1006

Message
<timestamp>, [ICPD-1006], <sequence-number>,, INFO, <system-name>, iSCSI service
is
Probable Cause
Indicates the iSCSI service is enabled or disabled on the switch.
Recommended
No action is required.
Action
Severity
INFO

ICPD-1007

Message
<timestamp>, [ICPD-1007], <sequence-number>,, INFO, <system-name>, iSNSC service
is
Probable Cause
Indicates the iSNSC service is enabled or disabled on the switch.
Recommended
No action is required.
Action
Severity
INFO

ICPD-1008

Message
<timestamp>, [ICPD-1008], <sequence-number>,, INFO, <system-name>, iSCSI switch
(<domain id>) is <status>.
Probable Cause
Indicates the iSCSI switch is reachable or unreachable.
328
<status>
on the switch.
<status>
on the switch.
Fabric OS Message Reference
53-1001157-01

Advertisement

Table of Contents
loading