5
BL-1020
BL-1020
Message
<timestamp>, [BL-1020], <sequence-number>,, CRITICAL, <system-name>, Switch timed
out initializing the chips.
Probable Cause
Indicates that the switch has failed to initialize the application-specific integrated circuit (ASIC)
chips.
Recommended
Reboot or power cycle the switch.
Action
Run the systemVerification command to verify that the switch does not have hardware problems.
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric
OS Command Reference for more information on these commands.
If the message persists, replace the switch.
Severity
CRITICAL
BL-1021
Message
<timestamp>, [BL-1021], <sequence-number>,, INFO, <system-name>, Retry <Retry
Number>, internal port retry initialization, <List of internal ports retrying
initialization>.
Probable Cause
Indicates that the switch had internal ports not online and that the system is retrying to bring the
ports that failed back online.
Recommended
No action is required.
Action
Severity
INFO
BL-1022
Message
<timestamp>, [BL-1022], <sequence-number>,, CRITICAL, <system-name>, Init Failed:
Switch DISABLED because internal ports were not ONLINE,
number not ONLINE>.
Probable Cause
Indicates that the switch initiation failed because one or more of the internal ports was not online.
The switch is faulted.
Recommended
Reboot or power cycle the switch.
Action
Run the systemVerification command to verify that the switch does not have hardware problems.
Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric
OS Command Reference for more information on these commands.
Additional fault messages precede and follow this error, providing more information. See other
error messages for recommended action.
If the message persists, replace the switch.
Severity
CRITICAL
56
<list of internal port
Fabric OS Message Reference
53-1001157-01