71

RPCD-1004

RPCD-1004
Message
<timestamp>, [RPCD-1004], <sequence-number>,, WARNING, <system-name>, Invalid
certificate file. Secure RPCd is disabled.
Probable Cause
Indicates the SSL certificate file has been corrupted.
Recommended
To enable RPCD in Secure mode, install a valid SSL certificate the switch.
Action
Severity
WARNING

RPCD-1005

Message
<timestamp>, [RPCD-1005], <sequence-number>,, WARNING, <system-name>, Missing
private key file. Secure RPCd is disabled.
Probable Cause
Indicates the private key file is missing.
Recommended
Run the pkiCreate command to install a valid private key file.
Action
Severity
WARNING

RPCD-1006

Message
<timestamp>, [RPCD-1006], <sequence-number>,, WARNING, <system-name>, Permission
denied accessing private key file. Secure RPCd is disabled.
Probable Cause
Indicates the private key file configured on the switch could not be accessed because the root did
not have read-level access.
Recommended
Change the file system access level for the private key file and make sure that root has read-level
Action
access.
Severity
WARNING

RPCD-1007

Message
<timestamp>, [RPCD-1007], <sequence-number>,, WARNING, <system-name>, Invalid
private file. Secure RPCd is disabled.
Probable Cause
Indicates the private key file has been corrupted.
Recommended
Run the pkiCreate command to install a valid private key file.
Action
Severity
WARNING